M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
590
IB-1501279-H
Set the number of pulses per revolution of the motor side encoder.
When using the encoder interface unit MDS-EX-HR, use this with SP098(RNG2ex).
Encoder
TS5691(128 teeth): SP020 = 2000
TS5691(180 teeth): SP020 = 2880
TS5691(256 teeth): SP020 = 4000
TS5691(384 teeth): SP020 = 6000
TS5691(512 teeth): SP020 = 8000
TS5690( 64 teeth): SP020 = 2000
TS5690( 90 teeth): SP020 = 2880
TS5690(128 teeth): SP020 = 4000
TS5690(192 teeth): SP020 = 6000
TS5690(256 teeth): SP020 = 8000
TS5690(384 teeth): SP020 =12000
ERM280(1200 teeth): SP020 = 4800
ERM280(2048 teeth): SP020 = 8000
MPCI : SP020 = 7200
MBE205: SP020 = 2000
---Setting range---
When SP098=0, the setting range is from 0 to 32767 (kp)
When SP098
≠
0
For M800/M80 Series: 0 to 65535 (p)
Set the detection time constant of Overload 1 (Alarm 50). (For Mitsubishi adjustment)
Normally, set to "60".
Set to "300" when using an IPM spindle motor.
---Setting range---
1 to 15300 (s)
Set the current detection level of "Overload 1" (Alarm 50) as a percentage against the motor short-time rated
output current. (For Mitsubishi adjustment)
Normally, set to "120".
Set to "100" when using an IPM spindle motor.
---Setting range---
1 to 200 (Short-time rated %)
Set the excessive error detection width for the interpolation mode and spindle synchronization.
The standard setting is "120".
When set to "0", the excessive error detection will be ignored, so do not set to "0".
---Setting range---
1 to 32767 (°)
Set the in-position detection width.
Set the positioning accuracy required to the machine.
Lower setting value increases the positioning accuracy, but makes the cycle time (settling time) longer.
The standard setting is "875".
---Setting range---
0 to 32767 (1°/1000)
(PR)
#13020
SP020 RNG2
Main side encoder resolution
(PR)
#13021
SP021 OLT
Overload detection time constant
#13022
SP022 OLL
Overload detection level
#13023
SP023 OD1
Excessive error detection width (interpolation mode -
spindle synchronization)
#13024
SP024 INP
In-position width
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...