M800/M80/E80/C80 Series Alarm/Parameter Manual
1 Operation Errors (M)
12
IB-1501279-H
Details
Restart switch has been turned ON and manual mode has been selected before the restart search is complet-
ed.
Remedy
Search the block to restart.
Turn the restart switch OFF.
Details
The cycle start button was pressed during program check or in program check mode.
Remedy
Press the reset button to cancel the program check mode.
Details
The cycle start button was pressed during buffer correction.
Remedy
Press the cycle start button after the buffer correction is completed.
Details
The cycle start button was pressed during resetting or tape rewinding.
Remedy
When rewinding the tape, wait for the winding to end, or press the reset button to stop the winding, and
then press the cycle start button.
During resetting, wait for the resetting to end, and then press the automatic start button.
Details
The playback switch was turned ON during editing.
Remedy
Cancel the editing by pressing the input or previous screen key before turning ON the playback switch.
Details
The turning angle at the block joint exceeded the limit during normal line control.
In normal line control type I:
The parameter "#1523 C_feed" (Normal line control axis turning speed) has not been set.
In normal line control type II:
When turning in the inside of the arc, the set value for the parameter "#8041 C-rot. R" is larger than the arc
radius.
Remedy
Correct the program.
Correct the parameter "#1523 C_feed" (Normal line control axis turning speed) setting.
Correct the parameter "#8041 C-rot. R" setting.
Details
Any of the following conditions are occurring.
a) There is no block to run backward
b) Eight blocks without a travel command continued
Remedy
Execute forward run to clear the alarm.
Reset to clear the alarm.
M01
Restart switch ON
0111
M01
Program check mode
0112
M01
Cycle st. in buffer correct
0113
M01
In reset process
0115
M01
Playback not possible
0117
M01
Turn stop in normal line cntrl
0118
M01
Reverse run impossible
0119
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......