M800/M80/E80/C80 Series Alarm/Parameter Manual
1 Operation Errors (M)
13
IB-1501279-H
Details
The synchronous correction mode switch was pressed in non-handle mode.
Remedy
Select the handle or manual arbitrary feed mode.
Turn OFF the correction mode switch.
Details
The synchronous control operation method was set (with R2589) while no synchronous control option was pro-
vided.
Remedy
Set "0" for "synchronous control operation method".
Details
Cycle start was attempted before resetting was completed.
Computer link B operation was attempted at the 2nd or further part system in a multi-part system.
Remedy
Perform the cycle start after resetting has been completed.
Set "#8109 HOST LINK" to "0" and then set to "1" before performing the cycle start.
Computer link B operation cannot be performed at the 2nd or further part system in a multi-part system.
Details
The basic axis corresponding to the inclined axis was started simultaneously in the manual mode while the in-
clined axis control was valid.
Remedy
Turn the inclined axis and basic axis start OFF for both axes. (This is also applied for manual/automatic
simultaneous start.)
Disable the basic axis compensation, or command it to axes one by one.
Details
Machine lock was applied on the return axis being manually returned to the restart position.
Remedy
Cancel the machine lock and resume the operation.
Details
Orthogonal coordinate axis name does not exist.
Rotary axis name does not exist.
A duplicate name is used for the designated orthogonal coordinate axis.
The number of axes that were selected to change tool length compensation along the tool axis amount exceeds
the maximum number of axes.
The designated orthogonal coordinate axis name is the same as the rotary axis name.
Remedy
Correct the rotary axis configuration parameters.
Details
Cycle start was performed with an axis whose return to the restart position was not complete.
Remedy
Perform restart position return manually.
Validate the parameter "#1302 AutoRP" (Automatic return by program restart), then execute cycle start.
M01
In synchronous correction mode
0120
M01
No synchronous control option
0121
M01
Computer link B not possible
0123
M01
X/Z axes simultaneous prohibit
0124
M01
Program restart machine lock
0126
M01
Rot axis parameter error
0127
M01
Restart pos return incomplete
0128
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......