Select whether to execute the F command with a 1-digit code command or with a direct numerical command.
(The same value as "#1079 F1digt" will be reflected. When either setting changes, the other will change ac-
cordingly.)
0: Direct numerical command (command feedrate during feed per minute or rotation)
1: 1-digit code command (with the feedrate specified by the parameters "#1185 spd_F1" to "#1189 sp-
d_F5")
Select the method for the user macro interrupt.
(The same value as "#1229 set01/bit0" will be reflected. When either setting changes, the other will change
accordingly.)
0: The user macro interrupt of macro type
1: The user macro interrupt of sub-program type
Select the address E type when cutting an inch screw.
(The same value as "#1229 set01/bit1" will be reflected. When either setting changes, the other will change
accordingly.)
0: Specify the number of threads per inch for inch screw cutting.
1: Specify the precision lead for inch screw cutting.
For M system
Select the method of the arithmetic processing for the intersection point when the start-up or cancel com-
mands are operated during radius compensation.
(The same value as "#1229 set01/bit2" will be reflected. When either setting changes, the other will change
accordingly.)
0: The processing does not handle the start-up or cancel command block: handle the offset vector in the
direction vertical to that of the command instead.
1: The processing is executed for the intersection point between the command block and the next block.
For L system
Select the method of the arithmetic processing for the intersection point when the start-up or cancel com-
mands are operated during nose R or radius compensation.
(The same value as "#1229 set01/bit2" will be reflected. When either setting changes, the other will change
accordingly.)
0: The processing does not handle the start-up or cancel command block: handle the offset vector in the
direction vertical to that of the command instead.
1: The processing is executed for the intersection point between the command block and the next block.
Select the initial state after power-ON.
(The same value as "#1229 set01/bit3" will be reflected. When either setting changes, the other will change
accordingly.)
0: Constant surface speed control cancel mode.
1: Constant surface speed control mode.
Select whether to use the floating tap chuck in G74 and G84 tap cycles.
(The same value as "#1229 set01/bit4" will be reflected. When either setting changes, the other will change
accordingly.)
0: With a floating tapping chuck
1: Without a floating tapping chuck
Select an operation when the operation start point cannot be found while moving to the next block of G117.
(The same value as "#1229 set01/bit5" will be reflected. When either setting changes, the other will change
accordingly.)
0: The auxiliary function is enabled after the block for the movement has finished.
1: The program error (P33) occurs.
#8145
Validate F1 digit
#8155
Sub-pro interrupt
#8156
Fine thread cut E
#8157
Radius comp type B (M system) / Nose R comp type B (L system)
#8158
Init const sur spd
#8159
Synchronous tap
#8160
Start point alarm
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......