M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
377
IB-1501279-H
0: Master axis and slave axis determine their zero points individually.
1: The zero points of both master and slave axes are determined by initializing the master axis' zero point.
The slave axis moves in perfect synchronization with the master axis.
Set this to "1" for speed/current command synchronization control.
Set this in order to change the axis order of counter display.
If this is set, the axes will be displayed in ascending order.
However, axis whose setting is "0" will be displayed after axes whose settings are between "1" and "16" are
displayed.
(Note 1) When the same value is set for more than one axis, axis that is displayed on the left side on the
parameter screen will be first displayed.
(Note 2) When both of the mixed control (cross axis control) and interchange coordinate position display
("1280 ext16/bit2" OFF) are valid, and when there are two or more valid part systems, this parameter will
be ignored.
(Note 3) When the arbitrary axis exchange control (option) is ON, and when there are two or more valid part
systems, this parameter will be ignored.
---Setting range---
0: The axis is displayed after the axes whose settings are between "1" and "16" are displayed.
1 to 16: Axes are displayed in ascending order.
If the number other than "1" to "16" is set, it is dealt as "0" setting.
[M8]
Select the axis travel direction in the 2D graphic drawing (trace, check).
If set to 1, the positive/negative directions are reversed.
---Setting range---
0/1
[C80]
Not used.
[C80]
0: Zero point establishing operation is determined by #1493.
1: When both the master and slave axes reach the current limit during stopper-method zero point estab-
lishment with #1493 set to 1, droop is cancelled, and the operation goes into the next step.
[M8]
Specify the second letter of command axis name when the axis name extension parameter is valid "#1266
ext02/bit0 = 1".
The command axis name is not extended if this parameter is unspecified, and the only one letter set in "#1013
axname" or "#1014 incax" respectively is the absolute command axis name or incremental command axis
name.
Axis configuration should not be as the non-name extension axis (1-letter axis) after the name extension axis
(2-letter axis) in the part system.
(Configure the 2-letter axis after the 1-letter axis)
---Setting range---
A to Z (Setting is cleared when "0" is set)
[C80]
Not used.
(PR)
#1493
ref_syn
Synchronization at zero point initialization
(PR)
#1494
dsp_ax_change
Axis order of counter display
(PR)
#1495
grf_ax_direction
Axis travel direction in 2D graphic
(PR)
#1496
push_typ
Stopper method in zero point establishing operation
(PR)
#1601
axnameEx
Axis name extension letter
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......