M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
422
IB-1501279-H
bit0: Program restart method selection
Select the program restart type.
0: Restart type A
1: Restart type B
bit1: Change miscellaneous command completion method
Select the complete signal and completion condition.
0: Normal method
Complete at the falling edge of M function finish 1 signal (FIN1) or rising edge of M function finish 2
(FIN2).
1: High-speed method
Complete when High-speed M finish signal (MFIN1 to 4, SFIN1 to 6, TFIN1 to 4 or BFIN1 to 4) reaches
the same logical level as the strobe signal.
bit2: Change areas for stored stroke limit I
Enable/Disable change of the areas for stored stroke limit I.
0: Disable
1: Enable
bit3: Select M30 rewinding operation
Select the operation when the miscellaneous function completed signal (FIN) is returned to M30.
0: Not carry out automatic rewinding
1: Carry out automatic rewinding
bit4: Select M02 rewinding operation
Select the operation when the miscellaneous function completed signal (FIN) is returned to M02.
0: Not carry out automatic rewinding
1: Carry out automatic rewinding
bit5: M code output during high-speed simple program check
Select whether to enable M code output during high-speed simple program check.
The M codes to be output are those specified by "#1451 M[M031-000](SMLK)" to "#1466 M[M511-480](SM-
LK)".
0: Disable
1: Enable
bit7: Operation for circular radius error at perfect circle command
Select the operation to be performed when a perfect circle command is given and there is a difference be-
tween the start point and end point radii, but no difference between the start point and end point angles.
0: Linear interpolation from the start to the end point
1: Spiral interpolation from the start to the end point
(PR)
#1278
ext14
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......