M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
567
IB-1501279-H
[M8]
This parameter specifies which observation speed change signal is input in the drive unit. The observation
speed change signal corresponds to the following bits of the parameter.
bit0: Observation speed change signal 1 is connected.
bit1: Observation speed change signal 2 is connected.
bit2: Observation speed change signal 3 is connected.
If the axis receives no observation speed change signal, set to "0000".
(Note) When a same setting value is set to more than one axis, or when more than one BIT is set to turn ON
for one axis, the alarm (Y20 0027) will occur.
---Setting range---
0000 to 0004 (HEX)
[C80]
Not used.
Specify the short-time rated output of the spindle motor (for L-coil).
This value is used for calculating the power consumption of the spindle motor.
---Setting range---
0 to 99999999 (W)
Specify the short-time rated output of the spindle motor (for H-coil).
This value is used for calculating the power consumption of the spindle motor.
This parameter is used also when the coil switch function is OFF.
---Setting range---
0 to 99999999 (W)
Temporary error cancel calculation delay time
When a period of time set in this parameter has elapsed after turning-ON of the spindle chuck close (SPC-
MPC) signal, you can temporarily cancel spindle sync error by turning ON the spindle sync error temporary
cancel (SPDRPO) signal.
If the specified time has not elapsed when the spindle sync error temporary cancel (SPDRPO) signal is
turned ON, temporary cancel of spindle sync error is enabled first when the time of this parameter has
elapsed.
When 0 is set in this parameter, the delay time will be 284(ms).
---Setting range---
0 to 3000 (msec)
[M8]
Set the observation speed, which is at the machine end, in the multi-step speed monitor.
(Note) When the setting value is larger than 18000, the last 2 digits will be ignored.
Ex. 1234567 -> 1234500(deg/min)
---Setting range---
0 to 6553500 (deg/min)
[C80]
Not used.
(PR)
#3145
S_SigInSP
Safety observation signal input
#3146
RatedOutL(PwrCal)
Short-time rated output for power computation (L-coil)
#3147
RatedOutH(PwrCal)
Short-time rated output for power computation (H-coil)
(PR)
#3148
sycmpctm
Temporary error cancel calculation delay time
(PR)
#3149
spsscfeed5
Observation speed 5
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......