M800/M80/E80/C80 Series Alarm/Parameter Manual
4 MCP Alarms (Y)
80
IB-1501279-H
Details
The machine group Nos. that are used for the machine groupwise alarm stop function are different among the
axes related to inclined axis control and synchronous control.
Remedy
Give an identical machine group No. to all the axes related to inclined axis control and synchronous control.
Details
The machine group-based alarm stop function has been disabled, because both the machine group-based
alarm stop and collision detection functions were enabled.
Remedy
Disable the collision detection function if you wish to use the machine group-based alarm stop function.
Details
The 1st letter of name extension axis for 2-letter axis (#1013 axname) is specified to the basic axes I, J, and K
(parameter #1026 to #1028).
Remedy
Set the letter other than the 1st letter of name extension axis for 2-letter axis (#1013 axname) to the basic
axes I, J and K (parameter #1026 to #1028).
Details
The PC1 and PC2 settings for the rotary axis are too large.
Remedy
Correct "#2201 SV001 PC1 (Motor side gear ratio)" and "#2202 SV002 PC2 (Machine side gear ratio)".
Details
In the absolute/incremental command method using the axis address (L system and when "#1076 AbsInc" =
1), the axis that the same axis address is set in "#1013 axname" and "#1014 incax" exists.
Remedy
Correct the settings so that the same axis address is not set in "#1013 axname" and "#1014 incax".
Details
The axis address that is out of the setting range (other than X, Y, Z, U, V, W, A, B, C, H) is set in "#1013 ax-
name" or "#1014 incax".
Remedy
Set the axis address within the setting range to "#1013 axname" and "#1014 incax".
Details
There is an error in the spindle encoder signal.
The data transmission to the drive unit is stopped when this error occurs.
Remedy
Check the spindle encoder's feedback cable and the encoder.
Y51
Machine group No. discrepancy
0039
Y51
M-group alarm stop disabled
0040
Y51
Basic axes I, J, K error
0045
Y51
Values of PC1/PC2 too large
0101
Y51
ABS/INC same axis name
0104
Y51
Axis name initial setting err
0105
Y90
No spindle signal
0001-0007
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......