M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
638
IB-1501279-H
Set the G code to be used when calling the macro with a G command.
Do not set a G code used in the system.
G101 to G110 and G200 to G202 are user macro I codes. However, if a parameter is set for the G code call
code, the G code call will have the priority, and these cannot be used as the user macro I.
---Setting range---
1 to 999
Set the macro call out type.
0: Equivalent to M98 P
∆∆∆∆
;
1: Equivalent to G65 P
∆∆∆∆
;
2: Equivalent to G66 P
∆∆∆∆
;
3: Equivalent to G66.1 P
∆∆∆∆
;
---Setting range---
0 to 3
Set the No. of the program or file name to be called out. The file name can contain up to 32 characters.
---Setting range---
Program name or file name (up to 32 characters)
The setting method is same as "#7201".
The setting method is same as "#7202".
The setting method is same as "#7203".
The setting method is same as "#7201".
The setting method is same as "#7202".
The setting method is same as "#7203".
The setting method is same as "#7201".
The setting method is same as "#7202".
The setting method is same as "#7203".
The setting method is same as "#7201".
The setting method is same as "#7202".
The setting method is same as "#7203".
The setting method is same as "#7201".
The setting method is same as "#7202".
#7201
G[01] Code
#7202
G[01] Type
#7203
G[01] Program No.
#7211
G[02] Code
#7212
G[02] Type
#7213
G[02] Program No.
#7221
G[03] Code
#7222
G[03] Type
#7223
G[03] Program No.
#7231
G[04] Code
#7232
G[04] Type
#7233
G[04] Program No.
#7241
G[05] Code
#7242
G[05] Type
#7243
G[05] Program No.
#7251
G[06] Code
#7252
G[06] Type
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......