background image

www.HunterFan.com

1.888.830.1326

Model #99112

Universal Ceiling Fan 

Remote Control

Installation

Wiring

OR

OR

OR

OFF

Remove the canopy. If uncertain 
how to remove it, reference the fan’s 
owner’s manual. With wiring exposed, 
it may be helpful to note existing wire 
connections or take a digital photo for 
reference. Remove the wire connectors 
that connect the wires from the outlet 
box to the fan, leaving the grounding 
wires connected. 

CONNECT WIRES FROM RECEIVER TO FAN -

Using the blue wire connectors connect the white wire from the 

receiver (marked “common out”) to the white wire from fan. Connect the black wire from the receiver (marked 
“fan out”) to the black wire from the fan. Connect the blue wire from the receiver (marked ”light out”) to the 
blue wire (or possibly black with white stripe) from the fan. 

Note:

 The red wire from the receiver has a pre-installed wire terminator.  It will not be used. 

If you’re uncertain about wire colors or connections, please contact a qualified electrician.

CONNECT WIRES FROM RECEIVER TO WIRES FROM OUTLET BOX

 - Using an orange wire connector connect 

the black wire (ungrounded) from the ceiling to the black wire from the receiver (marked “live in”). Connect 
the white wire (grounded) from the ceiling to the white wire from the receiver (marked “neutral in”). 

AFTER ALL WIRES ARE CONNECTED 

and secured with wire connectors, re-install the canopy. 

Before installing the 
Universal Remote 
Control, use the pull 
chains to turn the light 
ON. Be sure power is OFF 
before proceeding with 
installation.

Choose the hanging system that most closely resembles the one used by your fan and install the receiver and wire as directed. 

Note:

 Some fans may have considerable excess lead wire. For easier canopy installation, cut the excess wire, leaving a minimum of 8” remaining. Re-strip the fan lead wires 1/2”. Place remaining excess 

wire into the ceiling electrical box. 

The bracket and fan must remain properly grounded.  

You may have installation issues if the fan is installed on an angled ceiling.

Ceiling

Plate

Receiver

Canopy

Receiver

Canopy

Ceiling

Bracket

Receiver

Fan Body

Cable Tie

For low profile fans, the receiver should 

be secured to the hanger bracket with 

a cable tie.

Receiver

Canopy

Turn the splices upward and push them carefully back through the hanger bracket 
into the outlet box. Spread the wires apart, with the grounded wires on one side of 

the outlet box and the ungrounded wires on the other side of the outlet box.

To avoid possible electrical shock, before installing or servicing your fan, disconnect the 
power by turning off the circuit breakers to the outlet box and associated wall switch 
location. If you cannot lock the circuit breakers in the off position, securely fasten a 
prominent warning device, such as a tag, to the service panel.

FR

OM

 RECEIVER

 

FRO

M CEILING

black (ungrounded)

white (grounded)

white (neutral in)

black (live  in)

FR

OM

 RECEIVER

white

black

blue

white (common out)

black (fan out)

blue (light out)

FROM FAN

M0034-01 • 09/05/12 • © Hunter Fan Company