In this section:
Introduction .............................................................................. 9-1
KXCI communications connections .......................................... 9-2
Using KCon to configure KXCI ................................................. 9-3
Starting KXCI and the GPIB command interpreter ................... 9-5
Using KXCI ............................................................................... 9-6
Logging commands, errors, and test results ............................ 9-6
Graphing the test results .......................................................... 9-9
GPIB command set ................................................................ 9-10
GPIB command reference ...................................................... 9-13
Ethernet command reference ................................................. 9-49
SMU default settings .............................................................. 9-50
System Mode SMU default settings ....................................... 9-51
Output data formats ............................................................... 9-52
Status byte and serial polling ................................................. 9-54
Sample programs ................................................................... 9-56
GPIB error messages ............................................................. 9-58
KXCI pulse generator commands .......................................... 9-59
KXCI CVU commands ............................................................ 9-66
Calling KULT user libraries remotely ...................................... 9-81
Introduction
The Keithley External Control Interface (KXCI) allows you to use an external computer to remotely
control the SMUs and pulse generator cards in the 4200A-SCS. You can use remote control over the
general-purpose instrument bus (GPIB) or ethernet. You define the type of communications in KCon
(in the KXCI Settings options). When controlled by an external computer, the 4200A-SCS functions
like any other GPIB instrument.
This section contains:
•
KXCI user interface: Describes how to use the KXCI user interface, which is used to control GPIB
operation.
•
GPIB command set: The command strings to control the source-measure operations of the
4200A-SCS are summarized in three tables.
•
GPIB command reference: Provides detailed reference information on the command set.
•
Ethernet command reference: Describes the command set that can be used for Ethernet
communications.
•
SMU default settings: Describes how to return the SMUs to their power-on default settings.
Includes a table that lists the default settings.
•
Output data formats: Describes the format of the data string that returns measured readings to
the computer for both system mode and user mode.
Section 9