Serial port
Configure Modbus mode
LR54 User Guide
253
3. Set the type of parity used by the device to which you want to connect:
(config)>path-paramparity
parity
(config)>
Allowed values are:
n
even
n
odd
n
none
The default is
none
.
4. Set the stop bits used by the device to which you want to connect:
(config)>path-paramstopbits
bits
(config)>
5. Set the type of flow control used by the device to which you want to connect:
(config)>path-paramflow
value
(config)>
where value is one of:
n
none
n
rts/cts
n
xon/xoff
7. Click
Apply
to save the configuration and apply the change.
The
Apply
button is located at the top of the WebUI page. You may need to scroll to the top of
the page to locate it.
Command line
1. Select the device in Remote Manager and click
Actions
>
Open Console
, or log into the LR54
local command line as a user with full Admin access rights.
Depending on your device configuration, you may be presented with an
Access selection
menu
. Type
admin
to access the Admin CLI.
2. At the command line, type
config
to enter configuration mode:
> config
(config)>