Serial port
Configure Remote Access mode
LR54 User Guide
216
7. Set the number of data bits used by the device to which you want to connect:
(config)>path-paramdatabits
bits
(config)>
8. Set the type of parity used by the device to which you want to connect:
(config)>path-paramparity
parity
(config)>
Allowed values are:
n
even
n
odd
n
none
The default is
none
.
9. Set the stop bits used by the device to which you want to connect:
(config)>path-paramstopbits
bits
(config)>
10. Set the type of flow control used by the device to which you want to connect:
(config)>path-paramflow
value
(config)>
where value is one of:
n
none
n
rts/cts
n
xon/xoff
11. Save the configuration and apply the change:
(config)> save
Configuration saved.
>
12. Type
exit
to exit the Admin CLI.
Depending on your device configuration, you may be presented with an
Access selection
menu
. Type
quit
to disconnect from the device.
Configure Remote Access mode
Remote Access
mode allows for remote access to another device that is connected to the serial port.
To change the configuration to match the serial configuration of the device to which you want to
connect:
Web