Diagnostics
Configure options for the event and system logs
LR54 User Guide
1002
3. Click
System
>
Log
.
4. (Optional) To change the
Heartbeat interval
from the default of 30 minutes, type a new value.
The heartbeat interval determines the amount of time to wait before sending a heartbeat
event if no other events have been sent.
Allowed values are any number of weeks, days, hours, minutes, or seconds, and take the
format
number
{
w|d|h|m|s
}.
For example, to set
Heartbeat interval
to ten minutes, enter
10m
or
600s
.
To disable the
Heartbeat interval
, enter
0s
.
5. (Optional) To disable event categories, or to enable them if they have been disabled:
a. Click to expand
Event Categories
.
b. Click an event category to expand.
c. Depending on the event category, you can enable or disable informational events, status
events, and error events. Some categories also allow you to set the
Status interval
, which
is the time interval between periodic status events.
6. (Optional) See
for information about configuring remote syslog
servers to which log messages will be sent.
7. Enable
Preserve system logs
to save the current session's system log after a reboot.
By default, the LR54 device erases system logs each time the device is powered off or
rebooted.
Note
You should only enable
Preserve system logs
temporarily to debug issues. Once you are
finished debugging, immediately disable
Preserve system logs
to avoid unnecessary wear to
the flash memory.
8. Click
Apply
to save the configuration and apply the change.