Set Value Generators
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
Baumüller Nürnberg GmbH
374
3.6
3.6.2.2 Description of the Parameters
132.1
Mode
Control of the set value generator
Number
Name
Type
Min
Max
Default Value
Unit
Factor
R
ead o
n
ly
St
o
ra
g
e
D
S
Supp
ort
C
yclic W
rite
A
x
is-in
d
ep
end
e
nt
132.1
Mode
DWORD 0
0xFFFFFFFF 0
1:1
X
132.2
Status
DWORD 0
0xFFFFFFFF 0
1:1
X
132.3
Output
FLOAT
-5000000000
5000000000
0
1:1
X
132.4
Target number output
UDINT
0
0xFFFFFFFF 0
1:1
X
132.10
Set value 1
FLOAT
-5000000000
5000000000
0
1:1
X
132.11
Duration zone 1
UDINT
1
4294967295
1000
ms
1:1
X
132.12
Set value 2
FLOAT
-5000000000
5000000000
0
1:1
X
132.13
Duration zone 2
UDINT
1
4294967295
1000
ms
1:1
X
132.14
Set value 3
FLOAT
-5000000000
5000000000
0
1:1
X
132.15
Duration zone 3
UDINT
1
4294967295
1000
ms
1:1
X
132.16
Set value 4
FLOAT
-5000000000
5000000000
0
1:1
X
132.17
Duration zone 4
UDINT
1
4294967295
1000
ms
1:1
X
Bit #
Meaning
0
0: Deactivate set value generation
1: Activate set value generation
1
Processing only when set value generation activated (bit 0 = 1):
0: Switch on set value generation only when drive enabled
a)
1: Always switch on set value generation
a)
Drive state P108.6 = 4 ("Operation Enabled")
2
0: Looped operation: the set value generator starts again with the first set
value after the last phase has elapsed.
1: Single cycle: the generator runs through only one cycle of the preset set
value profile. At the end, the last set value is held.
31…3
Reserved