3.7
18.77
Position actual revolutions for fieldbus
The parameter displays the revolution number of the actual position value and is updated
in the fieldbus cycle.
This parameter corresponds to
; however is latched in the controller at the fitting
transfer time of the actual position value. Therefore, it is primarily intended to be an actual
fieldbus value, for the fieldbus especially if an own position error monitoring shall be cal-
culated on the control.
18.78
Torque set value for OM current control
(from FW version 1.14)
At the current control operating mode (
= -2 and if the option "Specification by
torque set value" is active:
bit 5 = 1, the controller receives the torque input from
this writable parameter. The parameter value referring to the torque setting can be en-
tered by the parameter interface (ProDrive), the analog inputs or by the fieldbus.
Standardization: 100% accord to the "Torque reference value"
18.84
w3 Filter frequency nominator
Nominator frequency of the filter for the acceleration feedforward.
18.85
w3 Filter damping nominator
Nominator damping of the filter for the acceleration feedforward.
18.86
w3 Filter frequency denominator
Denominator frequency of the filter for the acceleration feedforward.
18.87
w3 Filter damping denominator
Denominator damping of the filter for the acceleration feedforward.
18.88
Set value filter frequency nominator
Nominator frequency of the set value filter