Description of the Software Modules and Parameters
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
297
3
14 ERROR RESPONSE ACTIVE
ERROR
n
Event:
m
Error response is complete
n
Action:
m
Drive function is inhibited
15 ERROR
SWITCH ON INHIBIT
n
Event:
m
"Reset Error" command
n
Condition:
m
Error is no longer present
n
Action:
m
Reset of error is carried out
The change of state only takes place if the actions have been fully carried out. The se-
quence of actions corresponds to their execution during the change of state. The next
state is reached after complete processing of the actions and new commands are accept-
ed.
m
Smooth torque reduction
This parameter can be set to provide smooth torque reduction using controlled braking
procedures.
m
Parking axis
If a controller in the Fieldbus network is operated without a motor or encoder, the output
of errors (display, error LED) can be suppressed by activating the "Parking axis" display
state.
In the "Parking axis" display state, a "P" is displayed and the error LED remains off. This
is also the case when errors occur. However errors and the drive state continue to be sig-
naled as usual by means of the status word and the error parameters. The transition to
other drive states as State 1 (Switch-on Inhibit) or State F (Error) is not possible.
After the "Parking Axis" display state is exited, the actual drive state (1 or F) will be dis-
played again. Error and warning messages will be transmitted and displayed as usual
(display, error LED). Changing to other states will be possible again.
The "Activate Parking Axis" and "Cancel Parking axis" requests are transmitted using the
Parking axis Control Word parameter
. The state and errors for the requests are
signaled by the Parking Axis Status Word parameter
.
The controller will only accept the "Activate Parking Axis" command if the following con-
ditions have been satisfied:
n
Controller is in Drive State 1 (Switch-on Inhibit) or Drive State F (Error)
n
Drive is at a standstill (N=0 threshold under-run)
The "Cancel Parking Axis" command will be accepted if the controller is in the "Parking
Axis" display state.
If the controller is switched off in the "Parking Axis" display state, this state will be re-es-
tablished at the next switch-on.