3
9 … 4
Configuration setting of the combined measured values (if bit 1 = 0)
x bits revol (32 - x) bits angle:
Value:
0:
32 bits angle
1:
1 bit revol 31 bits angle
2:
2 bits revol 30 bits angle
3:
3 bits revol 29 bits angle
4:
4 bits revol 28 bits angle
5:
5 bits revol 27 bits angle
6:
6 bits revol 26 bits angle
7:
7 bits revol 25 bits angle
8:
8 bits revol 24 bits angle
9:
9 bits revol 23 bits angle
10:
10 bits revol 22 bits angle
11:
11 bits revol 21 bits angle
12:
12 bits revol 20 bits angle
13:
13 bits revol 19 bits angle
14:
14 bits revol 18 bits angle
15:
15 bits revol 17 bits angle
16:
16 bits revol 16 bits angle
17:
17 bits revol 15 bits angle
18:
18 bits revol 14 bits angle
19:
19 bits revol 13 bits angle
20:
20 bits revol 12 bits angle
21:
21 bits revol 11 bits angle
22:
22 bits revol 10 bits angle
23:
23 bits revol 9 bits angle
24:
24 bits revol 8 bits angle
25:
25 bits revol 7 bits angle
26:
26 bits revol 6 bits angle
27:
27 bits revol 5 bits angle
28:
28 bits revol 4 bits angle
29:
29 bits revol 3 bits angle
30:
30 bits revol 2 bits angle
31:
31 bits revol 1 bit angle
32:
32 bits revolutions
10 … 15 Reserved
19 … 16 Source for DS402 touch probe 1 (TP1)
/
, object 0x60BA / 0x60BB)
Value:
0:
Encoder 1 trigger digital input TP1
1:
Encoder 1 trigger digital input TP2
2:
Encoder 1 trigger zero pulse
3:
Encoder 2 trigger digital input TP1
4:
Encoder 2 trigger digital input TP2
5:
Encoder 2 trigger zero pulse
6 … 15: Reserved
Bit