Commissioning
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
43
2
33
34
Click on "Start".
35
Wait until "Successful" appears in the Status field.
36
Next click on "Stop/Off".
37
Check that the measured value corresponds to the value expected
(With Baumüller motors: resolver: 330° + 5°, sine-cosine: 240° ± 5°).
38
This completes all the parameter setting work for the specimen commissioning. You can
now satisfy yourself that the device is functioning correctly by having the motor rotate
briefly.
WARNING!
Risk of injury due to moving components!
Rotating and/or linearly moving components can cause serious injuries.
If the motor is not rotating freely, the motor and parts connected to it may be dam-
aged/destroyed.
Therefore:
m
Make sure that the motor can rotate freely during commissioning.
m
Do not interfere with moving components during operation.
m
Do not open covers during operation.
m
The residual mechanical energy depends on the application. Driven components
will continue to rotate/move for a certain time, even after the energy supply has
been switched off. Provide appropriate safety devices.