Description of the Software Modules and Parameters
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
373
3
3.6.2
Set Value Generator
Function
The set value generator generates a constant set value for each of 4 time zones. The set
value and the time for each zone are adjustable.
The set value generator can write to all cyclic writable parameters. With the time, the is-
sue time for the respective set value is set.
If the set value generator switches over the current positioning set of the axis (
=
), the time specifies the length of time spent in the target position.
Furthermore it is possible to determine whether the set value generator will start again
with the first time zone after the last time zone has elapsed (looped operation), or whether
only one cycle is run through and the last set value is preserved.
Thus the following speed set value sequence can be produced, for example:
Figure 94:
Speed set value sequence for set value generator
The set value generator has a cycle time of 1 ms. It can always be switched on or only
when the drive is enabled. Starting always takes place with the first set value in the preset
profile.
3.6.2.1 Parameter overview
Functional block:
FbSwg [132]
rev
min
t
Time 1
Time 2
Time 3
Time 4
Set value 1
Set value 2
Set value 3
Set value 4
Set value 1