3.8.5.2 Description of the Parameters
149.1
Status
Status of the spindle positioning
Number
Name
Type
Min
Max
Default Value
Unit
Factor
R
ead o
n
ly
St
o
ra
g
e
D
S
Supp
ort
C
yclic W
rite
A
x
is-in
d
ep
end
e
nt
149.1
Status
DWORD 0
0xFFFFFFFF 0x0
1:1
X
149.2
Mode
DWORD 0x0
0xFFFFFFFF 0x0
1:1
X
149.3
Spindle angle position
UDINT
0
0x0000FFFF
0
Inc
1:1
X
X
149.4
Spindle positioning
speed
UDINT
0.0625
32767.0000
100.0000
Inc/ms 10000:1
X
149.5
Spindle acceleration
bipolar
UDINT
0.07
655.35
2.00
Inc/
ms
2
100:1
X
149.6
Spindle maximum jerk
UDINT
0.07
655.35
0.25
Inc/
ms
3
100:1
X
149.9
Spindle relative offset
UDINT
0
0x0000FFFF
0
Inc
1:1
X
149.10
Active target position
UDINT
0
0xFFFFFFFF 0
Inc
1:1
X
149.11
Output Position Set
Value
UDINT
0
0xFFFFFFFF 0
Inc
1:1
X
149.12
Output speed set value
DINT
-65535.0
65535.0
0
Inc/ms 1:1
X
149.13
Output acceleration set
value
DINT
-655.35
655.35
0
Inc/
ms
2
100:1
X
Bit-no.
Meaning
0
0: Spindle positioning switch off
1: Spindle positioning switch on
1
1: Position set value has reached active target position
function finished
3 …2
Reserved
4
1: Speed set value = 0
5
Reserved
6
1: Spindle positioning speed limited to maximum speed, see
Speed limit and
Max speed mech.
9 … 7
Reserved
10
1: In Position (set value reached)
11
Reserved
12
Start command acknowledge