Description of the Software Modules and Parameters
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
447
3
3.7.2.6 Description of the Parameters
29.1
Command
Switching the filter on/off.
If the filter parameterization is active as a biquad filter, then the filter coefficients cannot
be calculated / changed individually, but are connected to the parameters
. Furthermore, the coefficients are automatically calculated again during a
change of the RT0 cycle time (
29.2
Status
Display of filter status (on / off)
29.6
Input value
Displays the input to the filter.
29.7
Output value
Displays the output of the filter.
Bit
Meaning
1 ... 0
0: Switch off filter
1: Filter as a current set value filter
(Active mains rectifier unit: Switch on filter)
2: Filter directly following the speed controller
2
Filter parameterization as a biquad filter
3
Recalculate filter (if bit 2 = 1)
7 ... 4
Switch on/switch off PT
1
filter 1 to 4
10 ... 8
Switch on/switch off biquad filter 1 to 3
13 ... 11
Switch on/switch off notch filter 1 to 3
Value
Meaning
0
Filter is switched off
1
Filter is switched on