Meaning of the bits and the external source of the drive current limiting:
138.9
External limiting max. drive current
Display of the total current [in A] which has been reduced by an external limit. See "Bit-
mask of external drive current limit"
It the external limit is not active:
External limiting max drive current
>
138.9
<
= Maximum value (10000 A)
138.10
External limiting max field current amplitude
Display of the field current [in A] which has been reduced by an external limit of the drive
current. See "Bit mask of external drive current limit"
.
If there is no external limit active:
External limiting max field current amplitude
>
138.10
<
= Maximum value (10000 A)
138.11
Iq set value before notch filter
The Iq set value at the input of the notch filter is shown in this parameter.
138.12
Center frequency Iq set value notch filter
Setting of the center frequency of the Iq set value of the notch filter. The filter is switched
off, when the value is less than 2 Hz.
Bit
Current limit from
0
Main power error; phase failure
1
Reserved
2
PU overload monitoring
3
Reserved
4
Moving to positive stop command
5
Homing to a mechanical stop
6
Peak current derating
15 ...7.
Reserved