Summary of all Parameters
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
Baumüller Nürnberg GmbH
776
5
Number
Name
Type
Min
Max
Default Value
Unit
Factor
R
ead o
n
ly
St
o
ra
g
e
D
S
Su
pp
ort
C
yclic W
rite
A
x
is-in
d
ep
end
e
nt
120.11
Homing blocking time
UINT
1
65535
100
s
100:1
X
120.12
Homing torque current
limit
UINT
0
10000
2500
%
100:1
X
120.13
Output speed set value
DINT
-65535
65535
0
Inc/ms 1:1
X
120.14
Output acceleration set
value
DINT
-65535
65535
0
Inc/
ms²
100:1
X
120.15
Encoder angle at refer-
ence switch
UDINT
0
0xFFFFFFFF 0
1:1
X
120.16
Homing max. position
delta to zero pulse
DINT
0
0x7FFFFFFF
0
Inc
1:1
X
X
120.17
Command
UDINT
0
1
0
1:1
121.1
Positioning general
mode
WORD
0x0
0xFFFF
0x0
1:1
X
121.2
Staus limit switch
WORD
0x0
0xFFFF
0x0
1:1
X
121.3
Negative SW limit
Switch
UDINT
0
0xFFFFFFFF 0x00010000
Inc
1:1
X
121.4
Positive SW limit switch UDINT
0
0xFFFFFFFF 0xFFFF0000
Inc
1:1
X
121.5
Positioning window
UDINT
0
0xFFFFFFFF 0x1000
Inc
1:1
X
121.6
Positioning window time UINT
0
65535
10
ms
1:1
X
121.7
Feedrate override
UINT
0
65535
10000
%
100:1
X
X
121.8
Stop Delay
UDINT
7
65535
200
Inc/
ms²
100:1
X
121.9
Positioning position
actual value
UDINT
0x0
0xFFFFFFFF 0x0
Inc
1:1
X
121.10
Maximum Position
Value
UDINT
0x0
0xFFFFFFFF 0xFFFFFFFF
Inc
1:1
X
121.11
Speed limit
UDINT
1
65535
3276
Inc/ms 1:1
X
O
121.12
Position actual value
revolutions with over-
flows
UDINT
0
0xFFFFFFFF 0
Inc
1:1
121.13
Input revolutions of load
gear
UDINT
1
0x7FFFFFFF
1
1.1
X
121.14
Output revolutions of
load gear
UDINT
1
0x7FFFFFFF
1
1:1
X
121.15
Modulo revolutions
UDINT
0
0x7FFFFFFF
1
1:1
X
121.16
Rotation position resolu-
tion
UDINT
0
0x7FFFFFFF
3600000
1:1
X
121.17
Modulo position actual
value
UDINT
0
0xFFFFFFFF 0
1:1
X
121.18
Status
DWORD 0x0
0xFFFFFFFF 0x0
1:1
X
121.19
Speed actual value load
basis
FLOAT
-2147483648
2147483647
0
Grad/s 1:1
X
121.20
Coarse position window UDINT
0
0xFFFFFFFF 0x2000
Inc
1:1
X
121.21
Command positive stop
drive
WORD
0x0
0x1
0x0
1:1
X