Description of the Software Modules and Parameters
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
693
3
The corresponding axis can be addressed through the SubDevice Index. The internal
controller ring buffer is organized 3-dimensional accordingly.
If no data is present in the ring buffer, the Read command response with error code:
RC_ERR_RSP_NODATA (1305)
If an attempt is made to read data from the buffer during recording, the Read command
responds with error code: RC_ERR_RSP_NOREAD (1304)
Index 0 of the 2nd dimension points to the most current value.
101.24
Task number
Display in which the ring buffer recording is carried out:
1:
62.5 µs time dials
2:
1 ms RT1