b maXX
BM5800
Document No.: 5.16029.03
Baumüller Nürnberg GmbH
348
3.5
3.5.5.2 Description of the Parameters
111.1
Status
For all speed and position controlled operating modes in the OPERATION ENABLED
state, the set value manager is switched on.
In operating modes such as, e.g., current control it thus remains switched off.
Number
Name
Type
Min
Max
Default Value
Unit
Factor
R
ead o
n
ly
St
o
ra
g
e
D
S
Supp
ort
C
yclic W
rite
A
x
is-in
d
ep
end
e
nt
111.1
Status
WORD
0x0000
0xFFFF
0x0000
1:1
X
111.2
Position set value rev
SetValMgr
UDINT
0
0xFFFFFFFF 0
Inc
1:1
X
111.3
Position set value angle
SetValMgr
UDINT
0
0xFFFFFFFF 0
Inc
1:1
X
111.4
Speed set value Set-
ValMgr
DINT
0x80000000
0x7FFFFFFF
0
Inc/ms 1:1
X
111.5
Acceleration set value
SetValMgr
DINT
0x80000000
0x7FFFFFFF
0
Inc/
ms²
1:1
X
111.6
Interpolation mode
UINT
0
4
1
1:1
X
O
111.7
External speed feedfor-
ward
FLOAT
-180000
180000
0
Grad/s 1:1
X
111.8
External acceleration
feedforward
FLOAT
-2147483647
2147483647
0
Grad/
s
2
1:1
X
111.9
Jerk set value Set-
ValMgr
DINT
0x80000000
0x7FFFFFFF
0
Inc/
ms
3
1:1
X
Bit #
Meaning
0
0: Set value manager is switched off
1: Set value manager is switched on; the set value sources provide set val-
ues to the set value manager
3 … 1
Reserved
4
1: Set value setting by RT1 Task active; fixed cycle time of 1 ms
5
1: Set value setting by fieldbus task active; configurable cycle time
15 … 6
Reserved