![Baumuller b maXX BM5800 Parameter Manual Download Page 178](http://html.mh-extra.com/html/baumuller/b-maxx-bm5800/b-maxx-bm5800_parameter-manual_2711380178.webp)
Configuration
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
Baumüller Nürnberg GmbH
178
3.4
137.36
Alarm mask
The parameter is only valid for EnDat
encoders.
The supported error messages of the connected encoder type are shown here.
137.37
Alarm buffer
The parameter is only valid for EnDat
encoders.
The error messages of the connected encoder type are displayed in this parameter. The
encoder sends an error message if the malfunction can result in wrong position values.
The cause of error will be displayed in this parameter.
Not generally all error messages were supported (see
Alarm mask).
The controller responds to a set error bit with a corresponding error (error numbers 406
to 412).
Bit
Supported error messages
0
1: Illumination failure
1
1: Signal amplitude
2
1: Position value
3
1: Overvoltage
4
1: Undervoltage
5
1: Overcurrent
6
1: Battery defect
Residual
Reserved
Bit
Monitoring according to
0
1: Illumination failure
1
1: Signal amplitude faulty
2
1: Position value faulty
3
1: Overvoltage occurred
4
1: Undervoltage supply
5
1: Overcurrent occurred
6
1: Battery change needed
Residual
Reserved