![Baumuller b maXX BM5800 Parameter Manual Download Page 773](http://html.mh-extra.com/html/baumuller/b-maxx-bm5800/b-maxx-bm5800_parameter-manual_2711380773.webp)
Summary of all Parameters
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
773
5
Number
Name
Type
Min
Max
Default Value
Unit
Factor
R
ead o
n
ly
St
o
ra
g
e
D
S
Su
pp
ort
C
yclic W
rite
A
x
is-in
d
ep
end
e
nt
110.5
Input 16 bit
INT
-16384
16384
0
%
4000
hex
:
100%
X
X
X
110.6
Ramp-up time
UDINT
0
650000
0
ms
1:1
X
X
X
110.7
Ramp-down time
UDINT
0
650000
0
ms
1:1
X
X
X
110.8
Quick stop time
UDINT
0
650000
0
ms
1:1
X
X
X
110.9
S-curve ramp-up time
UDINT
0
650000
0
ms
1:1
X
X
X
110.10
S-curve ramp-down time UDINT
0
650000
0
ms
1:1
X
X
X
110.11
Smoothing
UINT
0
32767
0
ms
1:1
X
X
110.12
Set value zone
UDINT
0x0
0x80000000
0
%
400000
00
hex
:
100%
X
X
110.13
Maximum drive speed
FLOAT
1
1.06 3000
U/min
1:1
X
110.14
Output acceleration
FLOAT
-5000000000
5000000000
0
Inc/
ms²
1:1
X
110.15
Input max. amount
UDINT
0
1073741824
1073741824
%
400000
00
hex
:
100%
X
X
X
110.16
Input min. amount
UDINT
0
1073741824
0
%
400000
00
hex
:
100%
X
X
X
110.17
Input 32 bit additive
DINT
-1073741823
1073741823
0
%
400000
00
hex
:
100%
X
X
X
110.20
Controlled stop time
UDINT
0
65000
1000
ms
1:1
X
X
X
110.21
SS1 stop time
UDINT
0
650000
0
ms
1:1
X
X
X
110.22
Active cycle time ramp
generator
FLOAT
0
8.0
1
ms
1:1
X
111.1
Status
WORD
0x0000
0xFFFF
0x0000
1:1
X
111.2
Position set value rev
SetValMgr
UDINT
0
0xFFFFFFFF 0
Inc
1:1
X
111.3
Position set value angle
SetValMgr
UDINT
0
0xFFFFFFFF 0
Inc
1:1
X
111.4
Speed set value Set-
ValMgr
DINT
0x80000000
0x7FFFFFFF
0
Inc/ms 1:1
X
111.5
Acceleration set value
SetValMgr
DINT
0x80000000
0x7FFFFFFF
0
Inc/
ms²
1:1
X
111.6
Interpolation mode
UINT
0
4
1
1:1
X
O
111.7
External speed feedfor-
ward
FLOAT
-180000
180000
0
Grad/s 1:1
X
111.8
External acceleration
feedforward
FLOAT
-2147483647
2147483647
0
Grad/
s
2
1:1
X
111.9
Jerk set value Set-
ValMgr
DINT
0x80000000
0x7FFFFFFF
0
Inc/
ms
3
1:1
X
114.1
DC link controller set
value
FLOAT
10
850
850
V
1:1
X
114.2
Kp DC link controller
FLOAT
0.001
256
0.01
1/V
1:1
X