![Baumuller b maXX BM5800 Parameter Manual Download Page 260](http://html.mh-extra.com/html/baumuller/b-maxx-bm5800/b-maxx-bm5800_parameter-manual_2711380260.webp)
Configuration
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
Baumüller Nürnberg GmbH
260
3.4
147.2
Status master
Status of the master in torque coupling (at master functionality only, i.e.
Bit 1...0 = 01).
147.3
Status slave
Status of the slave in torque coupling (at slave functionality only, i.e.
Bit 1...0 = 10).
147.4
Coupling command master
Coupling command from the master to the slave at torque coupling.
This parameter must be sent cyclic from the master to the slave.
At external master-slave communication this parameter must be sent via cross commu-
nication (fieldbus) or digital inputs/outputs. See also
256.
At internal master-slave communication an external transmission is not required.
The master transmits the command „Switch on torque coupling“, when the coupling is ac-
tivated basically (
Bit 0 = 1) and the master drive is enabled.
Bit
Meaning
0
0: Master functionality is switched off
1: Master functionality is switched on
15 ... 1
Reserved
Bit
Meaning
0
0: Slave functionality is switched off
1: Slave functionality is switched on
3 ... 1
Reserved
4
Torque coupling between master and slave
0: Coupling is switched off
1: Coupling is switched on
15 ... 5
Reserved
Bit
Meaning
0
0: Torque coupling is switched off
1: Torque coupling is switched on
15 ... 1
Reserved