Description of the Software Modules and Parameters
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
563
3
3.8.3
Operating mode Homing
An in depth knowledge of the absolute position of the drive is generally required to oper-
ate positioning drives. If an incremental encoder is used for position actual value record-
ing or if more than one motor revolution is necessary for the actual value recording with
tilt encoder for the entire traversing range, homing is required. Homing can also be used
to initialize the position actual value recording with absolute value encoders.
Drive guided referencing is addressed below. With drive guided homing runs, the process
control and movement of the motor is controlled by the drive itself and the reference
switch is thereby activated. This is implemented as a separate operating mode in the
b maXX
.
The homing runs usually use a switch as a reference mark. For more accuracy, the zero
mark of the encoder is included; however, homing runs without consideration of the zero
mark are possible.
The zero pulse is used as the zero mark with incremental encoders. The mechanical zero
angle is used with tilt encoders and sine-cosine encoders. The mechanical zero angle
thereby means 0° in the parameter mechanical angle actual value
.
Either one of the two end switches (negative or positive hardware end switch) or a sepa-
rate zero point switch may be used as the reference switch. The type of referencing
(switch, activation direction, etc.) is adjusted through parameter
Reference ad-
justing mode. The different homing methods thereby correspond with the drive profile of
CANopen.
3.8.3.1 Procedure of a homing under consideration of Zero pulse or Zero angle
A sample procedure of the homing to the negative end switch under consideration of the
zero pulse / zero angle is described below. The procedure of the other homing runs cor-
responds with this procedure. There are differences especially in the direction of travel
and sought after switch edge.
Figure 149:
Homing procedure to negative end switch with zero pulse