Description of the Software Modules and Parameters
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
219
3
131.53
Error counter fieldbus set values
Error counter for set value failures.
The counter is incremented at every set value failure. If the fieldbus is in operational state
and the drive is synchronous with the fieldbus, the error 1938 is set at exceeding of
threshold
.
131.55
Max error count fieldbus actual values
Error threshold for access conflicts at actual values.
This parameter configures how many access conflicts (actual values have been not re-
trieved) are necessary to set the error 1937.
131.56
Max error count fieldbus set values
Error threshold for set value failures.
This parameter configures how many set value failures (set values have been not written)
are necessary to set the error 1938.