3.4
124.2
Activation Command
Command to delete one or more measurements. The following actions will be performed
for the corresponding channel:
m
Deleting the associated status bit (measurement occurred / not occurred) in status
m
Setting measured values of individual channels to zero
m
Reactivation of an already (through Parameter 124.1) activated channel
Toggling the corresponding bit will trigger the command.
The parameter can be used to delete the indexes / latched values of the measuring en-
coder during active operation, but the application is not necessary.
Bit
Meaning
Encoder 1
0
0->1, 1->0:
Measurement Channel "Delete / reactivate Encoder 1 with Trigger digital
input TP1 positive edge
1
0->1, 1->0:
Measurement Channel "Delete / reactivate Encoder 1 with Trigger digital
input TP1 negative edge
2
0->1, 1->0:
Measurement Channel "Delete / reactivate Encoder 1 with Trigger digital
input TP2 positive edge
3
0->1, 1->0:
Measurement Channel "Delete / reactivate Encoder 1 with Trigger digital
input TP2 negative edge
4
0->1, 1->0:
Measurement Channel "Delete / reactivate Encoder 1 with Trigger Zero
Pulse positive edge
5
0->1, 1->0:
Measurement Channel "Delete / reactivate Encoder 1 with Trigger Zero
Pulse negative edge
6 ... 7
Reserved
Encoder 2
8
0->1, 1->0:
Measurement Channel "Delete / reactivate Encoder 2 with Trigger digital
input TP1 positive edge
9
0->1, 1->0:
Measurement Channel "Delete / reactivate Encoder 2 with Trigger digital
input TP1 negative edge
10
0->1, 1->0:
Measurement Channel "Delete / reactivate Encoder 2 with Trigger digital
input TP2 positive edge