4.5
1704
Analog limit values not available
Pulse block
1705
Internal I2C bus not functional
Pulse block
1706
Internal checksum error
Pulse block
1707
Encoder reset occurred through pro-
gram monitoring
Pulse block
1708
Counter overrun
Pulse block
1709
Parity error
Pulse block
1710
Checksum of transferred data is wrong
Pulse block
1711
Unknown command code
Pulse block
1712
Amount of transferred data wrong
Pulse block
1713
Transferred command argument not
permitted
Pulse block
1714
The selected data field may not be writ-
ten to
Pulse block
1715
Wrong access code
Pulse block
1716
Indicated data field size cannot be
changed
Pulse block
1717
Indicated word address is outside of
the data field
Pulse block
1718
No data field or addressed data field
does not exist
Pulse block
1728
Amount monitoring for analog signals
(process data)
Amount monitoring for analog signals (process data)
Pulse block
1729
Transmission current critical (contami-
nation, transmission break)
Transmission current critical (contamination, transmission break)
Pulse block
1730
Encoder temperature critical
Encoder temperature critical
Pulse block
1731
Speed too high, no position establish-
ment possible
Speed too high, no position establishment possible
Pulse block
1732
Speed too high, position can't be calcu-
lated
At rotatory encoders: position can't be calculated
At linear encoders: sensor is not adjusted or is not in adjustment
mode
Pulse block
1733
Position error Multiturn
At rotatory encoders: Position error Multiturn
At linear encoders: distance magnetic tape/sensor too high
Pulse block
1734
Position error Multiturn
At rotatory encoders: Position error Multiturn
At linear encoders: Positional error
Pulse block
1735
Position error Multiturn
Position error Multiturn
Pulse block
1752
Error while initializing the encoder
(multiple errors)
Error while initializing the encoder (multiple errors)
Pulse block
1753
Position generally not dependable
Encoder position not dependable. Quotient of resolution to line num-
ber faulty
Pulse block
1754
Unknown error from encoder
Unknown error code from the encoder
Pulse block
1755
Encoder file not existing
1756
File size too large for encoder
1800
no or invalid data in the encoder motor
type plate
The error occurs when no motor data can be read from the encoder
after rebooting.
Pulse block
1801
Invalid section found in the encoder
OEM memory
Invalid section found while reading the encoder memory. Reference
to wrong data in the OEM memory of the encoder.
Pulse block
Error
num-
ber
Brief error text
Error description
Default set-
ting for
Error
Response