3.6
168.3
Output
Output value of the Motor potentiometer.
This value is written directly to the ramp function generator parameter
Input
16 bit at activation of the Motor potentiometer.
168.4
Upper limit
Maximum value which is not exceeded in spite of activating the "Motor potent"
button.
This value must be greater than the value set in parameter
Motor potentiometer
lower limit. If this condition is not fulfilled, the input value is rejected.
168.5
Lower limit
Minimum value which is not fallen below in spite of activating the "Motor potentiometer-"
button.
This value must be less than the value set in parameter
Motor potentiometer up-
per limit. If this condition is not fulfilled, the input value is rejected.
NOTE!
If this limit is changed and the actual output value
is out of the area of the
limit value, at first activation of the "Motor potent" button (bit 1 of the param-
eter Motor potentiometer mode) the output value is set to the limit value (reduction of
speed).
NOTE!
If this limit is changed and the actual output value
is out of the area of the
limit value, at first activation of the "Motor potentiometer-" button (bit 2 of the param-
eter Motor potentiometer mode) the output value is set to the limit value (increase of