![Baumuller b maXX BM5800 Parameter Manual Download Page 169](http://html.mh-extra.com/html/baumuller/b-maxx-bm5800/b-maxx-bm5800_parameter-manual_2711380169.webp)
Description of the Software Modules and Parameters
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
169
3
106.75
Maximum harmonic
Maximum harmonic correction function. The basic vibration is corrected if the value is 0;
if the value is one then additionally the 2
nd
harmonic vibration is corrected. Deviations up
to the fourth harmonic vibration can be corrected at the maximum.
106.76
Amplitudes of the harmonics
Array including the amplitudes to correct the encoder angle as a harmonic function
whereat the index 0 stands for the amplitude of the 2
nd
harmonic vibration. The further
harmonics follow with a rising index.
106.77
Phases of the harmonics
Array including the phases to correct the encoder angle as a harmonic function whereat
the index 0 stands for the phase of the 2
nd
harmonic. The further harmonic vibrations fol-
low with a rising index.
106.78
Correction angle
Correction angle of excentricity and adding the individual harmonics, added to the encod-
er angle.
106.79
Speed for calculation of excentricity
By this speed the motor is operated during the evaluation of the excentricity or the indi-
vidual harmonics.
15
Error in calculation
16 ... 21
Internal calculation
22
Acceleration
23
Braking
24
Correction measurement
Status
Meaning