Management
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
Baumüller Nürnberg GmbH
352
3.5
111.9
Jerk set value SetValMgr
This parameter displays the jerk set value in the set value manager:
m
at speed controlled operating modes: from the second derivative of the speed set value
source
m
at position controlled operating modes: from the third derivative of the position set val-
ue source
Its resolution is 32 bit increments/revolution per ms