Record name
Freely usable string for naming the data set.
105.5
Record Id
Freely usable 32-bit value for identifying the data set.
105.6
Dataset Index
The number of the active data set is shown here. A write operation to this parameter re-
sults in switching the data set to the new data set.
The data set to which it is intended to switch must already be created, otherwise the value
will be rejected. Certain additional conditions must be satisfied in order to switch over
when the device is enabled.
105.7
Valid Datasets
Bit string to show which data sets are created. A set bit indicates a created data set.
166
RC_ERR_BAD_VALUE
Value is invalid
169
RC_ERR_NO_CHANGE
Value cannot be changed
172
RC_ERR_FORMAT
Byte length in the parameter set does not
agree with the byte length in the description
(parameter format changed?)
Value
RC Code
Meaning
Bit
Meaning
0
0: Data Set 1 deleted
1: Data Set 1 created
1
0: Data Set 2 deleted
1: Data Set 2 created
2
0: Data Set 3 deleted
1: Data Set 3 created
3
0: Data Set 4 deleted
1: Data Set 4 created
4
0: Data Set 5 deleted
1: Data Set 5 created