Configuration
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
Baumüller Nürnberg GmbH
82
3.4
Additionally, in the field weakening range the torque is limited by the maximum power.
Therefore, the maximum available torque
is constant in the base speed range.
In the field weakening range it decreases inversely proportional to the speed (see
Symmetric torque limit
The symmetric torque limit M
limit
) influences the set value of the torque current
controller, which controls the torque-generating current. The correspondent limit for the
torque-generating current I
sq limit M
will be fit as follows.
with
Flux
setl
Magnetic flux set value in %
Kt
upd
Kt
updated
, in Nm/A
Torque limits / torque current limits
Figure 33:
a) Asynchronous motor: Torque limit above
b) Asynchronous motor: Overlap of several limits
If there are several torque limits
, that result from the torque current limits
or from the breakdown torque-current limit op-
erating simultaneously then the smallest limit is decisive (compare
In
(b) the "Current mode" is assumed (
bit 3 = 1) with regard to the
parameters
,
Particular case synchronous motor with interior permanent magnet (IPMSM)
The torque is calculated from the characteristic map of the IPMSM and from the currents
according to the following formula:
I
sq limit M
M
limit
Kt
upd
Flux
set
[%]
--------------------------------------------
=
n [min ]
N
107.7
N
-1
N
max mech
107.26
max
M
m
[Nm]
(138.20)
M
n [min ]
N
107.7
N
-1
N
max mech
107.26
max
M
m
[Nm]
(138.20)
M
a)
b)
5000_0235_rev02_int
Lim
= (Iq
) =
f
Lim
(138.22)
Lim
min
(138.2,138.3,138.14,138.15)
Lim
(138.22)
M
|
|
|
|
f
(138.18)
base speed
range
field weakening
base speed
range
field weakening
effective
limits
=
M
Lim bd