3
122.2
Mode
16
Display of the master axis direction
0: positive
1: negative
17
1: Master axis position is extrapolated
31 … 18 Reserved
Bit
Function
Bit
Function
0
Automatical synchronization when starting
0: No, the positioning to the starting point is ensured by the PLC
1: Yes, the drive automatically positions to the starting point
1
1: Standstill monitoring of the master axis during synchronization is active
2
Type of synchronization after starting
0: Absolutely to the position
1: Absolutely to the angle
3
Consider the rotational direction during synchronization
0: Ignore rotational direction; positioning is made accordant to the shortest
distance
1: Consider rotational direction
4
Ignore rotational information of the master axis
5
Activation of reloaded curve files
0: Via the control word
1: Via the master axis angle at 0° (=rotational angle)
6
Delete curve data
7
Rotational rotation at synchronization
0: positive
1: negative
8
Reserved
9
Braking after activation for the operating mode switchover
0: No brake
1: Brakes activated
10
1: Extrapolation of the master axis position when set value failure, relevant
at virtual master axis only
11
1: Activation of the function "flexible segments" to change the traversing dis-
tances for selected segments during the curve movement
12
0: Virtual master axis: the master axis position is transmitted cyclically per
fieldbus
1: Real master axis: the master axis position is the actual value of the mas-
ter axis encoder