Target number output PID controller 2
Selection of the target of the PID controller output.
All cyclic writable parameters are permitted.
150.23
Kp PID controller 2
Proportional gain of the PID controller 2.
150.24
Tn PID controller 2
Integral action time of the PID controller 2.
150.25
Td PID controller 2
Derivative time of the PID controller 2.
150.26
Pt1 time constant PID controller 2
Time constant of the PT1 filter in the D leg of the PID controller. If the value „0“ is speci-
fied, the signal will be transmitted unfiltrated.
150.27
Output upper limit PID controller 2
Upper limit of the PID controller output.
If the output is limited with this limit, it will be signalized in
bit 4.
NOTE!
If the upper limit is greater than the maximum value of the linked target parameter,
then the output is limited at writing on the target parameter to the maximum value of
the linked target parameter if necessary. This will be signalized in
bit 8.