Management
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
Baumüller Nürnberg GmbH
318
3.5
3.5.2.3 Organization of the Parameters in the Data Sets
Within the device there are seven separate memory areas for parameters that have the
"Data Set" attribute (DS 1 to DS 7).
In addition there is a "window" which represents the current active data set (DS 0). One
of these seven data sets is always selected active. By writing to Parameter
Ac-
tive Data Set Number, Data Set 1, 2, 3, 4, 5, 6 or 7 can be selected to be active, hence it
is possible to switch between the data sets. In so doing, the window moves from DS 0 to
the memory area of the activated data set.
Example:
Data Set 3 is activated.
The "window" for the active data set addresses Data Set 3.
Figure 82:
Active data set
Basically, only data from the
active data set
(DS 0) can be accessed via external option
modules or fieldbuses.
3.5.2.4 Delivered State
When delivered, only Data Set 1 is created. The other data sets DS 2 to DS 7 are deleted.
The active data set (DS 0) is Data Set 1. All parameters have their standard values.
Switching to another data set is not possible.
After the device is configured, the parameters in the device should be saved. If an error
occurs while saving (e.g. as a result of switching off the device during the programming