Description of the Software Modules and Parameters
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
91
3
The maximum torque current I
sq max
(
>
19.8
<
) results from the max. drive current I
max aux
with subtraction of the field current I
sd aux
.
The max. drive current I
max aux
and the field current I
sd aux
are dependent of the motor
type and of the torque current standardized modes (parameter "Mode of Iq limit"
Bit 1 and Bit 3). The following modes are available:
m
Standard load factor mode
SM or ASM with
bit 1 = 0 (bit 3 = 0 from FW 01.13 of the controller):
I
max aux
= "Max. drive current actual value"
I
sd aux
= "Isd set value"
.
m
Load factor mode ASM-IsdMax
ASM only:
bit 1 = 1 (bit 3 = 0 from FW 01.13 of the controller):
I
max aux
= "Max. drive current actual value"
I
sd aux
= "Limit magnetizing current"
m
Current mode
(from controller FW 01.13 onwards)
bit 3 = 1 (independent of bit 1 and the motor type)
I
max aux
= "Max. drive current"
I
sd aux
= 0,
or I
sq max ref
*
>
19.8
<
= "Max. drive current"
NOTE!
The "Max. torque current"
>
19.8
<
is the standardized factor of the standardized
torque current limits of the parameters
,
and
, of the standardized torque current set values
as
well as of the standardized total current limit
I
sq max
I
max aux
2
I
sd aux
2
–
=