653
3
122.7
Start cam segment
Number of the polynomial which represents the start position of the master axis and the
drive.
122.8
Start position master revolution
Revolution of the master axis at the beginning of the starting segment.
122.9
Start position master angle
Angle oft he master axis at the beginning of the start segment.
122.10
Start position slave revolution
Revolutions of the drive at the beginning of the start segment.
122.11
Start position slave angle
Angle of the drive at the beginning of the start segment.
122.12
Maximum speed synchronization
The parameter value specifies the maximum speed of the overlaid synchronization move-
ment after starting the operation mode by which the drive is synchronized to the set po-
sition from the curve.
The resolution is 16 bit increments/revolution per ms.
122.13
Maximum acceleration synchronization
This parameter specifies the maximum acceleration of the synchronization movement in
Inc/ms2 described in
.
The resolution is 16 bit increments/revolution per ms