Description of the Software Modules and Parameters
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
177
3
Only measuring devices with Bit 0 = 1 and Bit 1 = 0 support the functions of EnDat
ver-
sion greater or equal 2.2.
137.31
Number of bits revolution counter
The parameter is set at EnDat
-, HIPERFACE
- and HIPERFACE DSL
- encoders on-
ly.
It displays the resolution of the digital position value (number of bits) in the area of revo-
lution of multiturn encoders.
The parameter displays 0 at singleturn encoders and length measuring devices.
137.32
Angle bits
The parameter is set at EnDat
-, HIPERFACE
- and HIPERFACE DSL
- encoders on-
ly.
It displays the resolution of the digital position value (number of bits) in the area of angle
at encoders or angle measuring devices.
137.33
Signal length
The parameter is set at EnDat
- and HIPERFACE
-length measuring device ("linear en-
coders") only.
It displays the length of a signal period in the unit nm.
137.34
Measure step 1
The parameter is set at EnDat
- and HIPERFACE
-length measuring device ("linear en-
coders") only.
The parameter displays the measuring step which will be output from the measuring in-
strument at the serial transfer of the position value. The unit is nm.
Bit
Meaning
1 ... 0
01: Instruction set type 2.2 is supported
3 ... 2
01: Safety relevant applications are supported
5 ... 4
01: Mode command "Measuring device receives comm. command" is sup-
ported
7 ... 6
01: Shutdown of instruction set type 2.2 is supported
Residual
Reserved