Management
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
Baumüller Nürnberg GmbH
302
3.5
m
Bit 9: Change of set value
n
Target Position Setting (Operating mode 1)
Change of set value with "set-of-set values"
0: Ongoing positioning operation is ended (target speed = 0; "Set Value reached" is
set) before the next operation is started.
1: Positioning with the current profile speed up to the current target and a running
start to the next positioning operation from this target.
m
Bit 11:
n
Manual drive operation (Operating mode 5):
1: Jog forwards
n
Target Position Setting (Operating mode 1)
1: Start positioning if control of positioning is via "Start positioning"
n
Position control (Operating mode -4):
1: Inhibit set values (Position set values which are written to P136.3/5 or P136.4/6
are not adopted)
n
Spindle positioning
Start of a sequential positioning
m
Bit 12:
n
Manual drive operation (Operating mode 5):
1: Jog backwards
n
Target Position Setting (Operating mode 1):
stop delay (FbPosCommonData)
n
Position control (Operating mode -4):
1: Inhibit set values (Position set values which are written to 136.3/136.5 or
136.4/136.6 are not adopted)
m
Bit 13:
For all operating modes: inhibit operating mode changeover
To avoid inconsistencies between the set operating mode and the mode-dependent bits,
the mode changeover can be inhibited selectively. When the bit is set, the set operating
mode remains active. Any intended change to the operating mode will only be adopted
when the bit is cleared. A new operating mode can thus be activated synchronously with
the control word. The instantaneous state of the mode changeover is indicated in
Status Word 2.
0: Enable mode changeover
1: Inhibit mode changeover