![Baumuller b maXX BM5800 Parameter Manual Download Page 737](http://html.mh-extra.com/html/baumuller/b-maxx-bm5800/b-maxx-bm5800_parameter-manual_2711380737.webp)
Error messages and troubleshooting
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
737
4
410
Undervoltage EnDat
interface
The error is triggered by the module EnDat
interface when the
absolute encoder reports via the EnDat
interface that the supply
voltage is too low.
m
Cause:
Cause for a encoder supply voltage that is too low may be cor-
roded contacts
n
Remedy:
Check encoder cable
m
Cause:
Cause can also be a defect in the encoder hardware.
n
Remedy:
Replace encoder.
Pulse block
411
Overcurrent EnDat
interface
The error is triggered by the module EnDat
interface when the
absolute encoder reports via the EnDat
interface that the encoder
supply current is too high.
m
Cause:
Cause for a encoder supply current that is too high may be an
internal short circuit.
n
Remedy:
Replace encoder.
Pulse block
412
Battery error EnDat
interface
The error is triggered by the module EnDat
interface when the Mul-
titurn absolute encoder reports via the EnDat
interface that the
supply battery must be replaced. The battery voltage provides posi-
tion information for the Multiturn encoder in the memory when the
controller is switched off and no supply voltage is provided for the
encoder.
m
Cause:
Cause for a battery replacement in the Multiturn encoder may be
a modification of the battery.
n
Remedy:
Replace encoder.
Pulse block
413
Alarm Bit set
EnDat
interface has set alarm Bit (collective message).
Pulse block
414
Error during reception: Address mirror-
ing returns an error
Error during reception: Address mirroring returns an error
Pulse block
415
Variance of encoder signals exceeds
adjustable limit
The variance of encoder signals exceeds adjustable limit
Pulse block
416
Touch probe: trigger zero pulse without
incremental encoder
The touch probe measurement is configured to trigger by a zero
pulse, but the used encoder does not provide a zero pulse.
m
Effect:
Value is not accepted
Response parameterizable
n
Acknowledgment:
No particular action
No response
417
Warning Collision of frequency
EnDat
encoder has messaged warning collision of frequency, see
; preventative maintenance is recommended.
No response
418
Warning Excess temperature
EnDat
encoder has messaged warning excess temperature; see
and error number 407; preventative maintenance is rec-
ommended.
No response
419
Warning Lighting controller reserve
reached
EnDat
encoder has messaged warning „Lighting controller reserve
reached“; see
and error number 406; preventative main-
tenance is recommended in order to avoid lighting failure.
No response
Error
num-
ber
Brief error text
Error description
Default set-
ting for
Error
Response