![Baumuller b maXX BM5800 Parameter Manual Download Page 121](http://html.mh-extra.com/html/baumuller/b-maxx-bm5800/b-maxx-bm5800_parameter-manual_2711380121.webp)
Description of the Software Modules and Parameters
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
121
3
Figure 41:
Torque ripple compensation
Before operation of the controller, an identification of the torque ripples can be made. The
required currents are measured here and then are preprocessed. Then the additional cur-
rent set values are saved in the table.
3.4.3.2.1
Parameter overview
Functional block:
FbOptimization [157]
Number
Name
Type
Min
Max
Default Value
Unit
Factor
Read
on
ly
St
o
ra
g
e
DS Su
ppo
rt
Cycl
ic W
rite
Axis
-ind
epen
den
t
157.1
Mode optimization
UINT
0
0xFFFF
0
1:1
X
157.2
State Identification
torque ripple compensa-
tion
UINT
0
0xFFFF
0
1:1
X
157.3
Table torque ripple cur-
rent
FLOAT
-1000
1000
0
A
1:1
X
157.6
Actual torque ripple cur-
rent
FLOAT
-1000
1000
0
A
1:1
X