Description of the Software Modules and Parameters
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
611
3
3.8.7.2 Description of the Parameter
145.1
Status
Remarks:
m
Bit 5 Slave axis stopped
145.5
Speed limit master shaft UDINT
0
0x7FFFFFFF 0x7FFFFFFF
Inc/
Tab
1:1
X
145.6
Synchronization veloc-
ity window
UDINT
1
2147483647
10000
Inc/ms 10000:1
X
145.7
Synchronization accel-
eration
UDINT
1
6553600
10000
Inc/
ms²
10000:1
X
X
145.8
Synchronization decel-
eration
UDINT
1
6553600
10000
Inc/
ms²
10000:1
X
X
145.9
Synchronization maxi-
mum jerk
UDINT
1
6553600
1000
Inc/
ms³
10000:1
X
X
145.10
Virtual master speed set
value
DINT
-2147483647
2147483647
0
Inc/ms 10000:1
X
145.11
Virt. master set value
cycle time
UINT
1
128
1
ms
1:1
X
145.12
Master speed
DINT
-2147483647
2147483647
0
Inc/ms 10000:1 X
145.13
Master position revolu-
tions
UDINT
0
0xFFFFFFFF 0
Inc
1:1
145.14
Master position angle
UDINT
0
0xFFFFFFFF 0
Inc
1:1
145.15
Master speed set value
additive 1
DINT
-2147483647
2147483647
0
Inc/ms 10000:1
X
145.16
Master speed set value
additive 2
DINT
-2147483647
2147483647
0
Inc/ms 10000:1
X
145.18
Master angle offset
DINT
0x80000000
0x7FFFFFFF
0x0
Inc
1:1
X
Bit #
Meaning
0
1: Synchronous operation is switched on
3 … 1
Reserved
4
1: Overspeed detected at the transmission input
5
1: Slave axis stopped
7 … 6
Reserved
8
0: Speed synchronization on master axis is completed
1: Speed synchronization on master axis is active
9
1: Slave axis is outside of the synchronization velocity window (
)
15 … 10 Reserved