Description of the Software Modules and Parameters
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
179
3
137.38
Warning mask
The parameter is only valid for EnDat
encoders.
The supported warnings of the connected encoder type are shown.
137.39
Warning buffer
The parameter is only valid for EnDat
encoders.
The warnings of the connected encoder type are displayed in this parameter. The ex-
ceeded requirements of tolerance for specific encoder internal values are displayed.
It is not assumed that position value are wrong at warnings contrary to error messages.
Not generally all warnings were supported (see
Warning mask).
The controller responds to a set warning with a corresponding error (error numbers 417
to 421). These can be always acknowledged.
Bit
Supported warnings
0
1: Collision of frequency
1
1: Excess temperature
2
1: Lighting controller reserve
3
1: Battery load
4
1: Reference point crossed
Residual
Reserved
Bit
Description
0
1: Collision of frequency
1
1: Excess temperature
2
1: Lighting controller reserve reached
3
1: Battery load to small
4
1: "Reference point crossed" will be supported
Residual
Reserved