Description of the Software Modules and Parameters
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
593
3
149.2
Mode
Mode of the spindle positioning
15 … 13 Reserved
19 … 16 State of the actual positioning process:
0: Switched off
1: Initialization at activation
2: Reserved
3: Slow down to spindle positioning speed
4: Spindle positioning speed reached, calculation of the target position
5: Calculate the target position at standstill (speed actual value = 0)
6: Positioning to active target position
7: Set value assignment completed
8: Initialization of a sequential positioning
9 to 14: Reserved
15: Error status
31 … 20 Reserved
Bit-no.
Meaning
Bit-no.
Meaning
1 … 0
Definition of the direction, if the speed actual value = 0:
If bit 4 = 0 „absolute positioning“
00: Towards greater position set values
01: Towards smaller position set values
10: Shortest distance
11: Reserved
If bit 4 = 1, „relative sequential positioning“; only bit 0 relevant
0: Towards greater position set values
1: Towards smaller position set values
3 … 2
Setting to spindle angle position or trigger source:
00: Positioning to
Spindle angle position
Residual: Reserved
4
Type of positioning for sequential positioning
0: absolute positioning
1: relative positioning
5
Speed profile
0: Trapezoidal
1: S-curve
31 … 6
Reserved